Combined Heat and Power Units

Electrical Safety for Operating Cogeneration Units with High Availability

Small but safe power packs for domestic use

A combined heat and power unit (CHP) is a modular system for the extraction of electrical energy and heat. This is operated at the point of heat consumption. It is based on the principle of combined heat and power. Combustion engines, e.g. diesel, vegetable oil or gas engines, gas turbines and Stirling engines can all be used as drive for the power generator. Ground fault protection and line isolation monitors work together to safeguard cogeneration units, allowing for quick detection of faults and reliable system performance. As with generators, the electrotechnical monitoring is based on the insulation level or on the existing fault current, depending on the supply system. Bender’s ground fault protection and insulation monitoring devices provide continuous monitoring to prevent electrical failures in combined heat and power units, ensuring safe operation and reduced downtime. The frequency and the voltage also need to be within a specific range in order to be able to be fed into the general power grid. By integrating insulation monitoring devices and line isolation monitors, operators can detect insulation faults early and maintain high system availability without interruptions.

Downloads

NameCategorySizeLanguageTimestampD-/B-Number
Product Overview ISOMETER®/ISOSCAN® Product Overviews 5.3 MB EN2024/02/1616.02.2024
Product Overview - Residual Current Monitoring Product Overviews 6.3 MB EN2024/10/2929.10.2024
Renewable Energy Market Segment Brochures 4.3 MB EN2017/02/2727.02.2017
Overview Brochure Product Overviews 10.3 MB EN2023/10/0202.10.2023
Bender Industry Applications Market Segment Brochures 5.9 MB EN2024/09/0404.09.2024

Products

Ground-Fault Monitoring, Ungrounded

ISOMETER® IR425-D4
ISOMETER® IR425-D4

Ground-fault monitoring device for ungrounded AC/DC control circuits

Ground-Fault Monitoring for Grounded Systems

LINETRAXX® RCMA420
LINETRAXX® RCMA420

AC/DC ground-fault monitor

Measuring and monitoring relays

LINETRAXX® VMD460-NA
LINETRAXX® VMD460-NA

Network and system protection (NS protection) for monitoring the power infeed of power generation systems

Ground-Fault Monitoring, Ungrounded

ISOMETER® IR425-D4
ISOMETER® IR425-D4

Ground-fault monitoring device for ungrounded AC/DC control circuits

Details

Ground-Fault Monitoring for Grounded Systems

LINETRAXX® RCMA420
LINETRAXX® RCMA420

AC/DC ground-fault monitor

Details

Measuring and monitoring relays

LINETRAXX® VMD460-NA
LINETRAXX® VMD460-NA

Network and system protection (NS protection) for monitoring the power infeed of power generation systems

Details

Standards

DIN EN 60255-127

Messrelais und Schutzeinrichtungen - Teil 127: Funktionsnorm für Über-/Unterspannungsschutz 

CEI 0-21

Regola tecnica di riferimento per la connessione di Utenti attivi e passivi alle reti AT ed MT delle imprese distributrici di energia elettrica (Reference technical rules for the connection of active and passive consumers to the HV and MV electrical networks of distribution Company)

VDE-AR-N 4105

Anwendungsregel:2011-08 Erzeugungsanlagen am Niederspannungsnetz Technische Mindestanforderungen für Anschluss und Parallelbetrieb von Erzeugungsanlagen am Niederspannungsnetz

C10/11

Specifieke technische aansluitingsvoorschriften voor gedecentraliseerde productie-installaties die in parallel werken met het distributienet

BDEW-Richtlinie 2008 einschl. Ergänzungen bis 01.2013
DIN VDE 0126-1-1/A1

Selbsttätige Schaltstelle zwischen einer netzparallelen Eigenerzeugungsanlage und dem öffentlichen Niederspannungsnetz (Norm wurde zurückgezogen und durch DIN VDE V 0126-1-1 ersetzt)

G59/2

Recommendations for the Connection of Generating Plant to the Distribution Systems of Licensed Distribution Network Operators

G59/3

Recommendations for the Connection of Generating Plant to the Distribution Systems of Licensed Distribution Network Operators

G83/2

Recommendations for the Connection of Type Tested Small-scale Embedded Generators (up to 16A per phase) in parallel with Low Voltage Distribution Systems

G83/3

Recommendations for the Connection of Type Tested Small-scale Embedded Generators (up to 16A per phase) in parallel with Low Voltage Distribution Systems