Automotive Engineering

Electrical Safety for the Automotive Industry

High availability in the automotive industry

The automotive industry is one of the driving forces behind the overall economy in America. Any amount of downtime in production must be prevented at all costs. Our ground fault protection and Insulation Monitoring devices provide comprehensive safety and reliability, crucial for maintaining continuous operations in the automotive industry. Potential electrical faults must be recognized early in order to prevent the system from shutting down. Bender fault current monitoring devices comply with the necessary standards to keep your facility operating, reducing maintenance costs, and keeping things on track.

Downloads

NameCategorySizeLanguageTimestampD-/B-Number
Product Overview ISOMETER®/ISOSCAN® Product Overviews 5.3 MB EN2024/02/1616.02.2024
Product Overview - Residual Current Monitoring Product Overviews 6.3 MB EN2024/10/2929.10.2024
2020 Guidelines (US) Technical Information 1.9 MB EN2020/06/1515.06.2020
Overview Brochure Product Overviews 10.3 MB EN2023/10/0202.10.2023
Electrical Safety in Control and Auxiliary Circuits Technical Article 632.6 KB EN2019/05/1313.05.2019
System Safety in Automobile Manufacturing Technical Article 649.7 KB EN2019/05/1313.05.2019

Products

Ground-Fault Monitoring, Ungrounded

ISOMETER® iso685…
ISOMETER® iso685 Series

Ground-fault detector for ungrounded AC/DC systems

Ground-Fault Monitoring for Grounded Systems

LINETRAXX® SmartDetect RCMS410

Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems

LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D Blindspot®

Multi-channel AC/DC ground-fault monitor

LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D Blindspot®

Multi-channel AC/DC ground-fault monitor with individual relay outputs

Current Transformers

LINETRAXX® CTUB100 Series

AC/DC sensitive measuring current transformer (Type B)

Ground-Fault Monitoring, Ungrounded

ISOMETER® iso685…
ISOMETER® iso685 Series

Ground-fault detector for ungrounded AC/DC systems

Details

Ground-Fault Monitoring for Grounded Systems

LINETRAXX® SmartDetect RCMS410

Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems

Details
LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D Blindspot®

Multi-channel AC/DC ground-fault monitor

Details
LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D Blindspot®

Multi-channel AC/DC ground-fault monitor with individual relay outputs

Details

Current Transformers

LINETRAXX® CTUB100 Series

AC/DC sensitive measuring current transformer (Type B)

Details

Standards

EN 61557-8

Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 8: Isolationsüberwachungsgeräte für IT-Systeme

EN 61557-9

Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 9: Einrichtungen zur Isolationsfehlersuche in IT-Systemen

EN 61557-15

Elektrische Sicherheit in Niederspannungsnetzen bis 1000 V AC und 1500 V DC - Geräte zum Prüfen, Messen oder Steuern von Schutzsystemen - Teil 15: Anforderungen an die funktionale Sicherheit von Isolationssteuergeräten in IT-Systemen und Geräten zur Erkennung von Isolationsfehlern in IT-Systemen

IEC 60204-1

Safety of machinery - Electrical equipment of machines - Part 1: General requirements