BHRG Series 1 are the simplest of Bender’s series of high resistance grounding systems. They integrate a neutral-grounding resistor (NGR) with optional pulsing function, NGR monitoring, and individual ground-fault detection for low-voltage power systems. NGR health is monitored with an RC48N Ground-Fault & NGR Monitor, an NGRM500 Neutral-Grounding-Resistor Monitor, or an NGRM700 Neutral-Grounding-Resistor Monitor. The former provides basic AC ground-fault and open-NGR detection. The NGRM series adds AC/DC ground-fault detection, harmonic analysis, two ground-fault detection levels, NGR-short detection, phase-voltage monitoring (NGRM700), communications, and a graphical display.
When an NGR monitor is not used, Bender RCM420 or RCMA423 ground-fault monitors detect AC and mixed AC/DC faults through the NGR. Bender RCMS460 or RCMS490 ground-fault monitors provide multiple-feeder monitoring to detect AC and DC faults in up to 12 circuits per device. The RCMS460 has common relay outputs; the RCMS490 adds dedicated relay outputs for each monitored channel.
Options include an audible alarm, a neutral-disconnect switch, and seismic rating.
BHRG Series 1 are the simplest of Bender’s series of high resistance grounding systems. They integrate a neutral-grounding resistor (NGR) with optional pulsing function, NGR monitoring, and individual ground-fault detection for low-voltage power systems. NGR health is monitored with an RC48N Ground-Fault & NGR Monitor, an NGRM500 Neutral-Grounding-Resistor Monitor, or an NGRM700 Neutral-Grounding-Resistor Monitor. The former provides basic AC ground-fault and open-NGR detection. The NGRM series adds AC/DC ground-fault detection, harmonic analysis, two ground-fault detection levels, NGR-short detection, phase-voltage monitoring (NGRM700), communications, and a graphical display.
When an NGR monitor is not used, Bender RCM420 or RCMA423 ground-fault monitors detect AC and mixed AC/DC faults through the NGR. Bender RCMS460 or RCMS490 ground-fault monitors provide multiple-feeder monitoring to detect AC and DC faults in up to 12 circuits per device. The RCMS460 has common relay outputs; the RCMS490 adds dedicated relay outputs for each monitored channel.
Options include an audible alarm, a neutral-disconnect switch, and seismic rating.
For assistance with ordering please contact Industrial.Sales@Bender-us.com or call (610) 383-9200.
Type | |
---|---|
An audible alarm | |
A neutral-disconnect switch | |
Seismic rating |
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
How to Size an NGR (US) | Technical Information | 424.0 KB | EN | 2019/05/1313.05.2019 | |
HRG & LRG Systems (US) | Product Brochures | 3.6 MB | EN | 2024/01/0303.01.2024 | |
NGR Checklist (US) | Technical Information | 245.3 KB | EN | 2022/11/0707.11.2022 | |
Guideline on NGRM Relay Testing | Technical Information | 522.3 KB | EN | 2021/10/2626.10.2021 |