COMTRAXX® COM463BC

  • Information exchange between BCOM and external BMS systems
  • Configuration of the information to be transferred from one system to the other
  • Several external BMS systems can be displayed together with BCOM systems in one overview

The COMTRAXX® COM463BC gateway is exclusively responsible for the data exchange between BCOM and BMS external systems. Data from external BMS systems automatically appear in the BCOM system and can be used there. It is also possible to distribute the data from the BCOM system to the BMS external systems, but this must then be configured individually.

Existing interfaces:

  • RS-485: BMS external
  • Ethernet: BCOM

Questions? Contact us!

COMTRAXX® COM463BC
COMTRAXX® COM463BC
  • Information exchange between BCOM and external BMS systems
  • Configuration of the information to be transferred from one system to the other
  • Several external BMS systems can be displayed together with BCOM systems in one overview

The COMTRAXX® COM463BC gateway is exclusively responsible for the data exchange between BCOM and BMS external systems. Data from external BMS systems automatically appear in the BCOM system and can be used there. It is also possible to distribute the data from the BCOM system to the BMS external systems, but this must then be configured individually.

Existing interfaces:

  • RS-485: BMS external
  • Ethernet: BCOM

Questions? Contact us!

Features

  • Gateway with web interface
  • Data exchange between devices at the following interfaces:
    – External BMS bus (max. 99 x 150 devices)
    – BCOM (max. 255 devices)
  • Remote display of present measured values and operation/alarm messages
  • Ethernet interface with 10/100 Mbit/s for remote access via LAN, WAN or the Internet
  • Assignment of individual texts for devices, channels (measuring points) and alarms
  • Device failure monitoring
  • E-mail notifications to various users in the event of alarms and system errors
  • 100 virtual devices with 16 channels each can be created. These are used to transfer information from a BCOM system to an external BMS.

Applications

  • Information exchange between BCOM and external BMS systems
  • Configuration of the information to be transferred from one system to the other
  • Several external BMS systems can be displayed together with BCOM systems in one overview
  • Selective notification to different users in case of alarms
  • Remote diagnosis, remote maintenance

COMTRAXX® COM463BC Variant(s)

TypeSupply voltage/
frequency range US
Power consumptionApplicationArt. No.
COM463BC-230VAC/DC 24…240 V, 50…60 Hz≤ 9.6 VA/≤ 4 WGateway for the connection of systems
with BCOM and external BMS
B95061051

Downloads for COMTRAXX® COM463BC

NameCategorySizeLanguageTimestampD-/B-Number
COM46x CE Declarations of Conformity 87.3 KB 2022/08/1212.08.2022
COM463BC Datasheets 10.1 MB EN2024/05/1515.05.2024D00427
COM463BC Manuals 13.1 MB EN2023/10/1111.10.2023D00427
COM463BC Quickstarts 1.1 MB EN2023/10/1111.10.2023D00427
COM463BC Update V4.9.7 Software 35.3 MB 2024/08/2929.08.2024D00427